Velux shutters are VELUX's own external roller shutters: the SSL solar shutter, which needs no wiring and fits manual and solar VELUX windows, and the SML electric shutter, which runs on 24 V from an electric VELUX window or control system. Both sit over the outside of the sash, are ordered by the size code on the window's data plate (MK04, SK06 and so on), and fit VELUX windows on roof pitches from 15° to 85°. Our price table puts a fitted VELUX roof window shutter at £450 to £950 in 2026. Plantation shutters rarely suit a pitched roof window: they sit inside the glass, so the heat is already in the room.
Key points
- No wiring in the loft: choose the SSL solar shutter. Electric VELUX window: choose the SML, which plugs into the window's own connection box.
- The size code (for example MK04: M is the width, 04 the height) is on the type sign behind the ventilation flap of the top sash.
- Windows made before 2001 can still take a VELUX shutter with a ZOZ 253 or ZOZ 254 installation kit.
- A roller shutter cannot go on a window with an extra element below it (GIL, GIU and similar) or a roof lantern.
Which Velux shutter for your window
Start with the window, not the shutter. VELUX's datasheets list which roof window types each shutter fits and the kits older windows need. This table turns those lists into a decision.
| Your window | Shutter to order | What to know |
|---|---|---|
| Manual VELUX window (GGL, GPL, GGU, GPU and similar), no power at the window | SSL solar roller shutter | No wiring. A pre-paired wall switch (KLI 313) comes in the box |
| VELUX solar window (solar GGL or GGU) | SSL solar roller shutter | Solar windows made before 2013 also need adaptor plate kit ZOZ 213 |
| VELUX electric window (electric GGL or GGU) | SML electric roller shutter | Plugs into the window's connection box; 24 V, 1.0 A |
| VELUX 3in1 window (GGLS or GPLS) | SSLS solar 3in1 roller shutter | Made for the three part window; solar GGLS also needs two ZOZ 246 switches |
| Window made before 2001 (old number codes such as 304) | SSL or SML with a kit | ZOZ 253 for sizes 101 to 206 (1991 to 2000), ZOZ 254 for older sizes |
| Window with an extra element below or beside it (GIL, GIU, GIR, GIV, GID) | None | VELUX says the roller shutter cannot be fitted. Use an interior blackout blind |
| Roof pitch under 15° or over 85° | None | Outside the range VELUX lists for SSL and SML |
| Roof lantern or flat rooflight | Not a roller shutter | See roof lanterns and flat rooflights below |
Two or more windows side by side need at least 100 mm between frames, and windows one above the other need at least 250 mm, for the shutters to fit. VELUX also makes both shutters to measure for sizes outside the standard list.
VELUX shutter codes: SSL, SML and SSLS
| Code | Drive | Power | Control | Notes |
|---|---|---|---|---|
| SSL | Solar | Solar cell in the top cover charges a 9.6 V NiMH battery; up to 100 operations on a full charge; battery life expected 10 years | Pre-paired wall switch; io-homecontrol, works with VELUX ACTIVE | Fits manual and solar VELUX windows with no wiring |
| SML | Electric | 24 V d.c., 1.0 A, from an electric VELUX window or a VELUX electric control system | Pre-paired wall switch; works with VELUX ACTIVE | Short motor cable connects straight to the window's connection box |
| SSLS | Solar | Same battery and solar cell as SSL | Pre-paired wall switch | Only for VELUX 3in1 windows GGLS and GPLS |
All three have foam filled aluminium slats in grey. The SSL and SML datasheets also list light grey slats and copper versions for copper clad windows. VELUX's datasheets say each can be installed from inside or outside, and its product page gives a guarantee of up to 5 years. VELUX also claims the shutter keeps a room up to 5 degrees cooler, the average from its own 2023 study across 28 European countries, based on two MK06 size windows in July and August; we have not tested that.
We found no manual VELUX roller shutter in VELUX UK's current technical library: the UK range there is solar and electric. If a quote names a manual VELUX shutter, ask the installer for its datasheet before you pay a deposit.
Reading the size code: CK02, MK04, SK06
Every VELUX roof window made since 1968 has a type sign in the right corner of the top sash, behind the ventilation flap. It gives the window type (for example GGL), the size, the variant and a production code. The size is what you order the shutter by. In current codes the letter is the width and the number is the height, and the K marks windows made since 2014.
| Size code | Width × height | Older codes for the same opening |
|---|---|---|
| CK02 | 55 × 78 cm | C02, 102 |
| CK04 | 55 × 98 cm | C04, 104 |
| FK06 | 66 × 118 cm | Check the type sign |
| MK04 | 78 × 98 cm | M04 (2001 to 2013), 304 (1992 to 2000) |
| MK06 | 78 × 118 cm | M06, 306 |
| MK08 | 78 × 140 cm | Check the type sign |
| PK08 | 94 × 140 cm | Check the type sign |
| PK10 | 94 × 160 cm | P10, 410 |
| SK06 | 114 × 118 cm | S06, 606 |
| UK04 | 134 × 98 cm | Check the type sign |
| UK08 | 134 × 140 cm | Check the type sign |
On solar VELUX windows made after June 2019, VELUX lists the SSL in the CK, FK, MK, PK, SK and UK widths; on solar windows made before that date it lists F, M, P, S and U widths only. Read the type sign rather than measuring the glass: blind and shutter sizes follow the window code, not the visible pane.
Solar, electric or manual
Solar is the usual retrofit choice because nothing needs wiring. The shutter charges itself from the cell in its box and runs from the wall switch that comes with it. The battery carries it through dull spells: VELUX says a full charge gives up to 100 operations without sun, and expects the battery to last 10 years.
Electric (SML) makes sense when the window is already an electric VELUX, because the shutter plugs into the window's own power. On a manual window it needs a separate VELUX electric control system and a cable run, which in a finished loft room is more work than the solar version. Any new mains circuit for that control system is electrical work covered by our guide to Part P and shutter motors.
Manual: as above, VELUX's current UK range is motorised. Older manual VELUX shutters still turn up on existing houses, and other makers' roof window shutters exist, but check the exact model against your window code before buying.
Why plantation shutters rarely suit a pitched roof window
A plantation shutter is a hinged panel inside the window. On a roof window that means the sun has already passed through the glass before the louvres stop it, which is why the European shading body ES-SO points to shading on the outside for heat. The panel also has to sit on a slope, clear the window's handle and opening sash, and stay shut against its own weight.
Some UK shutter firms do make plantation shutters for skylights. Shuttercraft says its skylight shutters fit to the window frame and can still be opened completely, and ShuttersUp makes them to measure in lighter materials for different angles. Neither gives a heat figure. They are a choice for the look and for light control, not for a hot loft bedroom.
What to use instead: for heat and darkness, a VELUX roller shutter outside. For sleep alone, an interior blackout blind made for the window. The two can be combined: VELUX says its roller shutters work with its interior blinds, although a solar interior blind behind a closed shutter charges less. If blackout is the main aim, see are plantation shutters blackout.
Your options compared
| Option | Heat | Blackout | Notes |
|---|---|---|---|
| VELUX SSL solar roller shutter | Blocks sun outside the glass | Yes | No wiring, the usual retrofit; £450 to £950 fitted on our price table |
| VELUX SML electric roller shutter | Blocks sun outside the glass | Yes | Best with an electric VELUX window |
| External heat protection awning | Cuts sun outside the glass | No | Mesh, keeps the view. Cannot be combined with a VELUX roller shutter |
| Interior blackout blind | Little: the heat is already inside | Yes | For sleep, not heat |
| Plantation shutters | Little: inside the glass | Partial | Specialist made to measure only; see above |
Why roof windows overheat
A roof window on a south facing slope receives far more direct sun in summer than a vertical window of the same size, because it faces the sky for most of the day. Loft bedrooms and dormer conversions are often the hottest rooms in the house for this reason. Our guide to shutters for dormers and loft conversions covers the rest of the loft.
Shading the outside of the glass is the most effective fix. ES-SO puts the cut in solar radiation from a fully lowered roller shutter at up to 96%.
Fitting and access
VELUX shutters clip to the window frame, with the box at the top of the window and the curtain running down the glass in side rails, so no masonry box or guides are needed. VELUX says they can be installed from inside or outside, so scaffolding is not normally needed for a typical loft window. Very high or awkward windows may need access equipment. Fitting is usually an hour or two per window.
If you are having new roof windows installed, ordering the shutter at the same time saves a visit and makes sure the sizes match. Local fitters are listed on our roof window shutters page.
The photo at the top of this page is VELUX's own image of its roller shutters on a pair of roof windows.
Roof lanterns and flat rooflights
Roof lanterns and flat glass rooflights over kitchen extensions are a different problem. A roller shutter for a pitched roof window does not fit them. The options are solar control glass, internal lantern blinds, or specialist external shading. Our guide to roof lanterns and roof window shading covers these.
Frequently asked questions
What shutters does VELUX make?
In the UK, the SSL solar roller shutter, the SML electric roller shutter and the SSLS solar shutter for 3in1 windows. All fit over the outside of the window.
Can you get shutters for Velux windows?
Yes. VELUX makes external roller shutters for its own windows, including windows made before 2001 with an installation kit, on roof pitches from 15° to 85°.
How do I find my Velux window size?
Open the window and look behind the ventilation flap in the right corner of the top sash. The type sign shows a code such as GGL MK04: order the shutter by the size part, MK04.
Is the solar Velux shutter better than the electric one?
Neither is better in general. Solar needs no wiring and suits manual windows. Electric suits windows that are already electric VELUX models, because it takes power from the window.
How much do Velux roller shutters cost?
Our price table puts a fitted VELUX roof window shutter at £450 to £950 in 2026, depending on size, drive and access.
Can you put plantation shutters on Velux windows?
Some specialists make them, but they sit inside the glass and do little for heat. An external VELUX roller shutter, or an interior blackout blind for sleep, is the usual choice.
Do roof window shutters need planning permission?
Usually not on an ordinary house, as they are small and fitted to an existing window, but check if the house is listed or in a conservation area.
Sources and further reading
- VELUX UK: anti-heat blackout shutter (product page, guarantee and cooling claim; source of the photo), checked 28 Nov 2026
- VELUX: solar roller shutter SSL datasheet (compatibility, kits, battery), checked 28 Nov 2026
- VELUX: electric roller shutter SML datasheet (compatibility, 24 V supply), checked 28 Nov 2026
- VELUX: solar 3in1 roller shutter SSLS datasheet, checked 28 Nov 2026
- VELUX UK technical library: SSL solar shutter, checked 28 Nov 2026
- VELUX UK: roof window sizes, checked 28 Nov 2026
- VELUX UK: where to find the type sign, checked 28 Nov 2026
- Less: VELUX window sizes and older equivalent codes, checked 28 Nov 2026
- Shuttercraft: skylight shutters, checked 28 Nov 2026
- ShuttersUp: plantation shutters for Velux windows and skylights, checked 28 Nov 2026
- ES-SO: roller shutters reduce solar radiation by up to 96% when fully extended
- GOV.UK planning guidance: when permission is required, permitted development and article 4 directions